FiscalNet
Equipment Catalogue · Tremol

Tremol Adpos M

Connection interfaces, device preparation, and configuration in FiscalNET.

Equipment and connections.

Tremol Adpos M
Cash register
Interfaces
Mini USB · RS-232 · Ethernet (LAN) · Wi-Fi / Bluetooth / GPRS, depending on the variant

The Adpos datasheet describes USB/RS-232 for PC and Ethernet for ANAF. Wi-Fi/Bluetooth/GPRS variants are also available; FiscalNET network communication is established for the installed configuration.

Preparing the device.

  1. Identify the name and serial number

    Check the Tremol Adpos M label, the distributor and the firmware. For the Tremol family, trade names and regional configurations may differ.

  2. Connect USB or RS-232

    The Adpos M20 datasheet confirms mini USB with a virtual COM port and RS-232 for PC. Use the cable for the computer port.

  3. Prepare the interface driver

    For USB, check the COM port in Windows and install the compatible Tremol driver, if necessary. Confirm the components required by the FiscalNET version separately.

  4. Configure the device and FiscalNET

    Confirm the operating mode, COM port and speed for the installed firmware, then configure the corresponding Tremol profile. Settings for third-party applications are not copied automatically.

  5. Check the response

    Close the other utilities that use the device and read the status from the FiscalNET configuration. Check the result before starting the sale.

Configuration in FiscalNET V3.

The screenshots show the application menus, not a connection tested with every model. Use your device’s parameters; on Android, confirm the supported profile and interface for the installed model.

Windows · V3 configuration
  1. Add the device and select Manual

    Open Fiscal Equipment → Cash Registers and tap + Add. Select Manual to complete the device profile and parameters. If the device already exists in the list, open its configuration.

    Choosing the addition method · FiscalNET V3 Windows · demonstrationEnlarge image
    Windows · Choosing the method of addition.
  2. Complete the device parameters

    Choose the profile that matches the model. For USB, select the device or the virtual COM port created by the driver; enter the speed only when the profile requires it. For RS-232, enter the COM port and the device speed. The values shown in the screenshot are examples.

    Configuration Form · FiscalNET V3 Windows · DemonstrationEnlarge image
    Windows · configuration form.

Save and check the response

Use Test Connection and check the device’s identification and status. Save the configuration after a correct response.

If the device is not responding
Android · V3 configuration
  1. Open the list of equipment

    In FiscalNET, open Case de marcat and tap +.

    List of cash registers · FiscalNET V3 Android · demonstrationEnlarge image
    Android · list of equipment.
  2. Choose manual configuration

    Select Manual to complete the profile and parameters. The test AMEF is a virtual device.

    Choosing the method of addition · FiscalNET V3 Android · demonstrationEnlarge image
    Android · Choosing the method of adding.
  3. Complete the device parameters

    Select the supported profile for the model and open the connection field.

    Configuration Form · FiscalNET V3 Android · DemonstrationEnlarge image
    Android · configuration form.
  4. Check the connection type

    Select the interface supported by the profile and enter the device parameters. For USB, select the device detected on Android.

    Choosing the USB/Serial or LAN/Wi-Fi connection · FiscalNET V3 Android · demonstrationEnlarge image
    Android · connection options.

Save and check the response

Use Test Connection and check the device’s identification and status. Save the configuration after a correct response.

If the device is not responding

Do you use FiscalNET V2? View the V2 configuration with images

If the device is not responding.

The USB device does not appear

Check the power supply, the data cable and the USB driver. If the driver creates a virtual COM port, check it in Device Manager.

The device is not responding

Check the operating mode and the device profile. For USB, check the device or the virtual port assigned by the driver. For RS-232, compare the COM port and the baud rate.

Connection busy or interrupted

Close the other programs that are using the device. After an interruption, check the status of the receipt before resending.

Do you need assisted configuration?

Send the device model, the connection used, the FiscalNET version, and the error message.

The next connection?
Your business.

Download FiscalNet and configure your equipment.