Custom BigPlus

Connection interfaces, device preparation, and configuration in FiscalNET.

Equipment and connections.

Custom BigPlus
Cash register
Interfaces
USB-B · RS-232 (COM1) · Ethernet (LAN)

COM1 is used for the PC; COM2 is for peripherals. If USB and RS-232 are connected simultaneously, the manual gives priority to USB.

Preparing the device.

  1. Identify the BIG PLUS ports

    The manual for Romania documents USB, RS-232 serial and Ethernet. Separate the PC port from the drawer port and select the cable corresponding to the configured interface.

  2. Prepare the cable and the driver

    Use the data cable specified for the device. If the USB connection creates a COM port, check its number in Device Manager → Ports (COM and LPT).

  3. Configure communication with the PC

    Choose USB, COM1 (RS-232) or Ethernet. Configure the PC channel in P910 and, for LAN, the IP address and port in P911, then enable FPU mode. COM2 is for peripherals.

  4. Configure the FiscalNET profile

    Use the confirmed profile for the model and the driver version. Copy the COM port and the configured baud rate; if the network connection is confirmed, use the IP address and port provided by the integrator.

  5. Check the result

    Start with a status read. Confirm that the device is responding correctly, then check the sales application and the response received for each command.

Configuration in FiscalNET V3.

The screenshots show the application menus, not a connection tested with every model. Use your device’s parameters; on Android, confirm the supported profile and interface for the installed model.

Windows · V3 configuration
  1. Add the device and select Manual

    Open Fiscal Equipment → Cash Registers and tap + Add. Select Manual to complete the device profile and parameters. If the device already exists in the list, open its configuration.

    Choosing the addition method · FiscalNET V3 Windows · demonstrationEnlarge image
    Windows · Choosing the method of addition.
  2. Complete the device parameters

    Select the profile that matches the model. For USB, select the device or the virtual COM port created by the driver; enter the baud rate only when the profile requires it. For RS-232, enter the COM port and the device speed. For the documented network, enter the IP address and the port of the device. The values in the screenshot are examples.

    Configuration Form · FiscalNET V3 Windows · DemonstrationEnlarge image
    Windows · configuration form.

Save and check the response

Use Test Connection and check the device’s identification and status. Save the configuration after a correct response.

If the device is not responding
Android · V3 configuration
  1. Open the list of equipment

    In FiscalNET, open Case de marcat and tap +.

    List of cash registers · FiscalNET V3 Android · demonstrationEnlarge image
    Android · list of equipment.
  2. Choose manual configuration

    Select Manual to complete the profile and parameters. The test AMEF is a virtual device.

    Choosing the method of addition · FiscalNET V3 Android · demonstrationEnlarge image
    Android · Choosing the method of adding.
  3. Complete the device parameters

    Select the supported profile for the model and open the connection field.

    Configuration Form · FiscalNET V3 Android · DemonstrationEnlarge image
    Android · configuration form.
  4. Check the connection type

    Select the interface supported by the profile and fill in the device parameters. For the network, use the configured IP address and port. Under USB, select the device detected on Android.

    Choosing the USB/Serial or LAN/Wi-Fi connection · FiscalNET V3 Android · demonstrationEnlarge image
    Android · connection options.

Save and check the response

Use Test Connection and check the device’s identification and status. Save the configuration after a correct response.

If the device is not responding

Do you use FiscalNET V2? View the V2 configuration with images

If the device is not responding.

The USB device does not appear

Check the power supply, the data cable and the USB driver. If the driver creates a virtual COM port, check it in Device Manager.

The device is not responding

Check the operating mode and the device profile. For USB, check the device or the virtual port assigned by the driver. For RS-232, compare the COM port and the baud rate. For the network, compare the IP address and the communication port.

Connection busy or interrupted

Close the other programs that are using the device. After an interruption, check the status of the receipt before resending.

Do you need assisted configuration?

Send the device model, the connection used, the FiscalNET version, and the error message.