FiscalNet
Equipment Catalogue · Datecs

Datecs DP-05 MX WiFi

Connection interfaces, device preparation, and configuration in FiscalNET.

Equipment and connections.

Datecs DP-05 MX WiFi
Cash register

Portable cash register with WiFi, battery and an easy-to-carry format. Datecs presents it for ridesharing services as well.

Interfaces
Micro USB · Wi-Fi · Bluetooth (optional)

Bluetooth requires the optional module. Wi-Fi is explicitly selectable for the PC connection in the model manual.

Preparing the device.

  1. Select the physical connection

    Choose micro USB or WiFi in the DP-05 MX WiFi configuration. Bluetooth remains an option dependent on the module fitted. The model does not provide connections for peripherals in section 13.5.1 of the manual.

  2. Prepare the computer

    Install the Datecs/DUDE components required by the FiscalNET version and the USB driver appropriate for the operating system. For a USB or serial adapter, identify the COM port in Device Manager.

  3. Set the connection in the device

    Open 4 Programming → 13 Configuration → 5 Communication → 2 PC Connection. In the manual, the selections are 1 for USB, 2 for Bluetooth and 3 for Wi-Fi; choose only the interface available on the device.

  4. Enable the computer module

    Return to the main menu and select 6 PC Connection. For USB, use the port identified in Windows; for WiFi, confirm the IP address and communication port in the configuration of the device and FiscalNET.

  5. Confirm communication

    Read the device status and check that there is no error or receipt left open. Close the configuration utilities before using the FiscalNET sales application.

Configuration in FiscalNET V3.

The screenshots show the application menus, not a connection tested with every model. Use your device’s parameters; on Android, confirm the supported profile and interface for the installed model.

Windows · V3 configuration
  1. Add the device and select Manual

    Open Fiscal Equipment → Cash Registers and tap + Add. Select Manual to complete the device profile and parameters. If the device already exists in the list, open its configuration.

    Choosing the addition method · FiscalNET V3 Windows · demonstrationEnlarge image
    Windows · Choosing the method of addition.
  2. Complete the device parameters

    Choose the profile that matches the model. For USB, select the device or the virtual COM port created by the driver; enter the speed only when the profile requires it. For the documented network, enter the IP address and the port of the device. The values in the screenshot are examples.

    Configuration Form · FiscalNET V3 Windows · DemonstrationEnlarge image
    Windows · configuration form.

Save and check the response

Use Test Connection and check the device’s identification and status. Save the configuration after a correct response.

If the device is not responding
Android · V3 configuration
  1. Open the list of equipment

    In FiscalNET, open Case de marcat and tap +.

    List of cash registers · FiscalNET V3 Android · demonstrationEnlarge image
    Android · list of equipment.
  2. Choose manual configuration

    Select Manual to complete the profile and parameters. The test AMEF is a virtual device.

    Choosing the method of addition · FiscalNET V3 Android · demonstrationEnlarge image
    Android · Choosing the method of adding.
  3. Complete the device parameters

    Select the supported profile for the model and open the connection field.

    Configuration Form · FiscalNET V3 Android · DemonstrationEnlarge image
    Android · configuration form.
  4. Check the connection type

    Select the interface supported by the profile and fill in the device parameters. For the network, use the configured IP address and port. Under USB, select the device detected on Android.

    Choosing the USB/Serial or LAN/Wi-Fi connection · FiscalNET V3 Android · demonstrationEnlarge image
    Android · connection options.

Save and check the response

Use Test Connection and check the device’s identification and status. Save the configuration after a correct response.

If the device is not responding

Do you use FiscalNET V2? View the V2 configuration with images

If the device is not responding.

The USB device does not appear

Check the power supply, the data cable and the USB driver. If the driver creates a virtual COM port, check it in Device Manager.

The device is not responding

Check the operating mode and the device profile. For USB, check the device or the virtual port assigned by the driver. For the network, compare the IP address and the communication port.

Connection busy or interrupted

Close the other programs that are using the device. After an interruption, check the status of the receipt before resending.

Do you need assisted configuration?

Send the device model, the connection used, the FiscalNET version, and the error message.

The next connection?
Your business.

Download FiscalNet and configure your equipment.